<input type=time> The time is not changing automatically from PM to AM and vice versa
Categories
(Core :: Layout: Form Controls, defect)
Core
Layout: Form Controls
Tracking
()
People
(Reporter: emilghitta, Unassigned)
Details
Attachments
(1 file)
2.34 MB,
image/gif
|
Details |
Found in
- 108.0a1 (BuildId:20221104042106)
Affected versions
- 102.4.0esr (BuildId:20221010114559)
- 106.0.4 (BuildId:20221102214123)
- 107.0b9 (BuildId:20221103190044)
- 108.0a1 (BuildId:20221104095303)
Tested platforms
- Affected platforms: Windows 10 64bit, macOS 11 & Ubuntu 22.04
Steps to reproduce
- Access the following webpage
- Click inside the time input field.
- Press the keyboard up arrow key until you reach 12.
- Press the keyboard down arrow key.
- Press the keyboard up arrow key until you reach the next 12 hrs mark.
Expected result
- Steps 4 & 5: The time changes from PM to AM again.
Actual result
- The time doesn't automatically change from PM to AM and vice versa.
Regression range
- I don't think that this is a regression. I can reproduce this issue with a build from 2018-01-01 as well.
Additional notes
- As a browser comparison, I cannot reproduce this issue in Google Chrome.